热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

GB/T 12745-1991 静力触探仪

作者:标准资料网 时间:2024-04-29 00:00:22  浏览:9870   来源:标准资料网
下载地址: 点击此处下载
基本信息
标准名称:静力触探仪
英文名称:Static penetrometer
中标分类: 仪器、仪表 >> 其他仪器仪表 >> 水文与水利仪器
ICS分类: 数学、自然科学 >> 地质学、气象学、水文学
替代情况:被GB/T 12745-2007代替
发布部门:国家技术监督局
发布日期:1991-03-21
实施日期:1991-10-01
首发日期:1991-03-21
作废日期:2007-09-01
主管部门:水利部
归口单位: 水利部
起草单位:河海大学
出版社:中国标准出版社
出版日期:1900-01-01
页数:平装16开, 页数:6, 字数:14000
适用范围

本标准规定了电阻应变式静力触探仪的设计、制造和试验方法。本标准适用于电阻应变式静力触探仪。该仪器的单用探头可测量土层的比贯入阻力,双用探头可分别测量土层的锥头阻力和侧壁摩阻力。

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 仪器 仪表 其他仪器仪表 水文与水利仪器 数学 自然科学 地质学 气象学 水文学
下载地址: 点击此处下载
Product Code:SAE J2832
Title:Welded Flash Controlled, High Strength (690 MPa Tensile Strength) Low Alloy Steel Hydraulic Tubing, Stress Relieved Annealed for Bending and Double Flaring
Issuing Committee:Metallic Tubing Committee
Scope:This SAE Standard covers stress relieved electric resistance welded flash controlled single wall high strength low alloy steel tubing intended for use in high pressure hydraulic lines and in other applications requiring tubing of a quality suitable for bending, double flaring and cold forming. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead. The grade of material produced to this specification is of micro-alloy content and is considerably stronger and intended to service higher pressure applications using thinner walls than like sizes of the grades of material specified in SAE J356, SAE J2435 and SAE J2613. Due to the alloy content of the material, the forming characteristics of the finished tube are equal to or better, when compared to SAE J356, SAE J2435 and SAE J2613. Nominal reference working pressures for this tubing are listed in SAE J1065.Caution: When brazing or welding is used as a tube end joining method, the structural integrity of the tube material can potentially be compromised due to the degradation of the areas affected by the thermal effect applied to the tubing; therefore, the SAE J1065 nominal reference working pressures may not be applicable.Brazed and/or welded tube assembly configurations made to specific geometry and components bill of material in association with this material, may require qualification testing in accordance with SAE J2658 Metallic Tube Conductor Assemblies for Fluid Power and General Use?Test Methods for Hydraulic Fluid Power Metallic Tube Assemblies. Cold forming the tube end configurations avoids this systemic testing by not compromising the tube material structural integrity.

版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1